Annual Tower Inspection Report Site NameHSVBlowOutWest Mountain Tower 3CamdenDate Inspected MM slash DD slash YYYY Bulb Replacement Bulb Replacement shall be performed for every incandescent beacon and obstruction lamp for each tower. Replacement shall be performed in conjunction with the tower and lighting inspection. Strobes and LED lighting shall only be replaced as needed. Contractor shall use only new, high-grade bulbs with Pyrex glass, long life, 130 volt rating. No reimbursement will be made to Contractor for bulbs installed during the bulb change. Indicate quantity and type of lamp (incandescent, LED or strobe) used on each tower.Beacon QtyBeacon TypeIncandescent 300WLEDStrobeSide Lamp QtySide Lamp TypeIncandescent 116W 130VLEDStrobeTower Lighting Controller and Alerting System TestDarken photocell to verify night-mode lighting activation Satisfactory Unsatisfactory Proper flashing or strobe of beacons and steady illumination of all obstruction lights Satisfactory Unsatisfactory Daytime lighting is functioning properly, where applicable Satisfactory Unsatisfactory Alarm system detects failure of tower lighting, as applicable at each tower site Satisfactory Unsatisfactory Light Controller ModelCustom IOT SolutionWhelenController Serail Number if AvailableElectrical and Lighting InspectionsProper functioning of photocell Satisfactory Unsatisfactory Proper functioning of flasher Satisfactory Unsatisfactory Proper functioning of ALL bulbs after replacement Satisfactory Unsatisfactory Inspect for damaged red obstruction lens Satisfactory Unsatisfactory Inspect for damaged ruby liner and clear glass lens in beacon Satisfactory Unsatisfactory Functioning of strobe light, if applicable Satisfactory Unsatisfactory All strobe lights are working Satisfactory Unsatisfactory Tower lighting electrical system Satisfactory Unsatisfactory Tightness of electrical screw terminals – Tighten loose connections Satisfactory Unsatisfactory Deterioration of insulation of electrical wiring Satisfactory Unsatisfactory Evidence of overheating of electrical wiring Satisfactory Unsatisfactory Bulb sockets condition Satisfactory Unsatisfactory Number of sockets replaced:Generator Check Does this site have a Generator? Yes No Name First Last By Entering your name you agree that all information is correctDate Completed MM slash DD slash YYYY Consent I agree to the best of knowledge, the information being submitted is true and accurate.NameThis field is for validation purposes and should be left unchanged. Δ